Aquajet, Aquajet Inox

Do not start the pump without having completely filled it with liquid.  Before starting up, check that the pump is properly primed; fill it completely with clean water by means of the hole provided after having removed the filler cap on the pump body. This ensures that the mechanical seal is well lubricated and that the pump immediately starts to work regularly. Dry operation causes irreparable damage to the mechanical seal. The filling cap must then be screwed back on carefully.  Switch on the power and check, on the three-phase version, that the motor is turning in the correct direction; this should be in a clockwise direction, looking at the motor from the fan side. If it is turning in the wrong direction, invert the connections of any two phase leads, after having disconnected the pump from the power mains. The electropump should not be started more than 20 times in one hour so as not to subject the motor to excessive thermal shock. Our AquaJet, AquaJetInox pumps are Jet, JetInox, pumps with some assembled accessories as a standard feature, we therefore refer you to the instruction manual for Jet pumps (also available in our DNA software).

Our AquaJet, AquaJetInox pumps are Jet, JetInox, pumps with some assembled accessories as a standard feature, we therefore refer you to the instruction manual for Jet pumps (also available in our DNA software).

If the motor does not start and makes no noise:

  • Check the electric connections.
  • Check the protection fuses.

 

If the motor does not start and makes no noise:

  • Look for possible blockages in the pump or motor
  • Check the condition of the capacitor
  • Check the electric connections

 

The pump does not prime:

  • Check that the intake pipe or the foot valve is not taking in air
  • Check the slope of the intake
  • Check that the pump body is filled
Troubleshooting AquaJet AquaJetInox
Troubleshooting AquaJet AquaJetInox

The direction of rotation must be checked only in three-phase pumps (therefore pumps powered at 400 volts). In single-phase pumps (230 volts) the motor always rotates in the correct direction. The manual explains the procedure for checking the direction of rotation, which must be clockwise. If it is turning in the wrong direction, invert the connections of any two phase leads, after having disconnected the pump from the power mains. Our AquaJet, AquaJetInox pumps are Jet, JetInox, pumps with some assembled accessories as a standard feature, we therefore refer you to the instruction manual for Jet pumps (also available in our DNA software).

AquaJet, AquajetInox verso di rotazione del motore

When replacing the power cable, a cable of the same type must be used (e.g. H05 RN-F or H07 RN-F depending on the installation) and with the same terminals, proceeding as for disassembly in inverse order. ATTENTION: depending on the installation and if the pumps have no cable, fit supply cables type H05 RN-F for indoor use and type H07 RN-F for outdoor use, complete with plug (EN 60335-2-41). For power cables without a plug, provide a device for cutting off the mains (e.g. magnetothermal device) with separating contacts of at least 3 mm for each pole.
Our AquaJet, AquaJetInox pumps are Jet, JetInox, pumps with some assembled accessories as a standard feature, we therefore refer you to the instruction manual for Jet pumps (also available in our DNA software).