FEKA 600

Remember that the electric pump must never run dry. Single-phase motors are equipped with thermal overload protection and are connected directly to the power supply, while in the case of three-phase pumps it is necessary to protect the pump with a circuit breaker (e.g. thermal magnetic circuit breaker) calibrated on the pump's data plate values. For three-phase motors only, it is always important to check the direction of rotation of the motorIf the rotation direction is wrong exchange two phase leads. We recommend you read the instruction manual of the Feka 600 (also available in our DNA software) for useful information for use, maintenance and installation.

The motor does not start and makes no noise.

  • Check the electrical connections
  • Check the protection fuses
  • Ensure that the float moves freely.

The pump stops after running a short time.

  • The thermal overload protection device stops the pump, immediately due to the density and temperature of the liquid.
  • Ensure that the intake grid, the impeller or the delivery pipe are not blocked or stuck.

It is normal to have a small leakage of water from the pump in operation as there is an anti-cavitation vent hole.

We recommend you read the instruction manual of the Feka 600 (also available in our DNA software) for useful information for use, maintenance and installation.

Feka 600 rotazione

The direction of rotation may be inverted only in three-phase pumps (therefore pumps powered at 400 volts). In single-phase pumps (230 volts) the motor always rotates in the correct direction. We recommend you read the instruction manual of the Feka 600 (also available in our DNA software) for all information on the product. In the case of Feka 600 pumps, the correct direction of rotation is the one that provides the highest flow rate. If not, invert any two phase leads, after having disconnected the pump from the power mains. We recommend you read the instruction manual of the Feka 600 (also available in our DNA software) for useful information for use, maintenance and installation.

Yes, you can. You must Provide power cables type H05 RN-F for indoor use and type H07 RN-F for outdoor use ( ≥10 mt) complete with plug. We recommend you read the instruction manual of the Feka 600 (also available in our DNA software) for useful information for use, maintenance and installation.