FK

This procedure applies to new installations as well as after service inspections if start-up takes place sometime after the pump was placed in the tank.

 

  • After long periods of storage, check the conditions of the oil in the oil chamber.
  • Check that the system, bolts, gaskets, pipework and valves etc. are in correct condition.
  • Mount the pump in the system.
  • Switch on the power supply.
  • Check whether the monitoring units, if used, are operating satisfactorily.
  • Check the setting of the float switches or of the level sensors.
  • Check that the impeller can turn freely by briefly starting the motor.
  • Check the direction of rotation.
  • Open the isolating valves, if fitted.
  • Check that the liquid level is above the motor for S1 operation and above the cable entry for S3 operation. If the minimum level is not reached do not start the pump.
  • Start the pump and let the pump run briefly, and check if the liquid level is falling.
  • Observe if the discharge pressure and input current are normal. If not, there might be air trapped inside the pump
FK level

We recommend you read the instruction manual of the FK (also available in our DNA software) for all information on the product.

FK troubleshooting
FK troubleshooting

We recommend you read the instruction manual of the FK (also available in our DNA software) for all information on the product.

Check the direction of rotation before starting up the pump. An arrow on the motor housing indicates the correct direction of rotation. Correct direction of rotation is clockwise when viewed from above.

Checking the direction of rotation

The direction of rotation should be checked in the following way every time the pump is connected to a new installation.

Procedure:

 

  1. Let the pump hang from a lifting device, e.g. the hoist used for lowering the pump into the tank.
  2. Start and stop the pump while observing the movement (jerk) of the pump. If connected correctly, the pump will rotate clockwise, i.e. it will jerk counter-clockwise. See figure below. If the direction of rotation is wrong, interchange any two of the phases in the power supply cable.
FK rotazione del motore

We recommend you read the instruction manual of the FK (also available in our DNA software) for all information on the product.

We recommend you read the instruction manual of the FK (also available in our DNA software) for all information on the product.