Europro High Flow

The pump is not sucking

  • No water in the pre-filter or clogged pre-filter
  • Closed valve in the pipes
  • Air getting into the suction pipe

Noisy pump

  • Air getting into the suction pipe
  • Presence of foreign bodies in the pump body
  • Cavitation

The pump is equipped with a filter that must be cleaned periodically, without pouring disinfectants and chemicals directly into the pump.

We recommend you read the instruction manual of the EuroPro High Flow (also available in our DNA software) for all information on the use of the product.

Installation, electrical connection and commissioning must be carried out by skilled personnel in compliance with the general and local safety regulations in force. Failure to comply with these instructions not only causes risk to personal safety and damage to the equipment, but invalidates every right to assistance under guarantee. 

For the three-phase pump, follow the wiring diagrams:

Europro High flow schemi elettrici

For three phase motors check the correct direction of rotation of the motor which must be clockwise. Otherwise invert any who phase leads, after having disconnected the electro pump from the power mains. We recommend you read the instruction manual of the EuroPro High Flow (also available in our DNA software) for all information on the use of the product.

Europro High flow senso di rotazione

Yes, you can. In the case of electropumps without a cable, provide power cables type H05 RN-F for internal use and type H07 RN-F for external use, complete with plug (EN 60335-2-41). We recommend you read the instruction manual of the EuroPro High Flow (also available in our DNA software) for all information on the use of the product.